做消防工程,非常怕“别人装啥我装啥”。机房、厨房、油库、大厂房,火险类型完全不同,系统不匹配,灭火瞬间变二次破坏。
When doing fire engineering, the biggest fear is' I'll do what others do '. The types of fire hazards in computer rooms, kitchens, oil depots, and large factories are completely different, and the systems are not matched, resulting in secondary damage in the instant of fire extinguishing.

记一张出彩简对照表:
Write a minimalist comparison table:
服务器机房、配电室、档案库:怕水怕粉,优先七氟丙烷/IG541气体灭火,或高压细水雾;普通喷淋直接排除。
Server room, distribution room, archive: afraid of water and powder, prioritize heptafluoropropane/IG541 gas fire extinguishing, or high-pressure fine water mist; Ordinary spray can be directly eliminated.
油罐区、化工车间、喷漆房:B类液体火,泡沫系统为主,干粉兜底;严禁直流水冲击。
Oil tank farm, chemical workshop, paint spraying room: Class B liquid fire, mainly foam system, dry powder at the bottom; Direct water impact is strictly prohibited.
商业厨房灶台:建议厨房专用湿化学药剂,用水浇油锅会爆沸。
Commercial kitchen stove: It is necessary to use kitchen specific wet chemical agents, as pouring water on the oil pot will cause it to boil.
体育馆、物流仓、中庭净高超12米:传统喷头够不着,上大空间智能探测+自动射流灭火装置。
Gymnasium, logistics warehouse, and atrium have a net height of 12 meters: traditional nozzles cannot reach them, so intelligent detection and automatic jet fire extinguishing devices are installed in large spaces.
普通商场、办公楼:湿式喷淋+消火栓+报警联动,性价比非常稳。
Ordinary shopping malls and office buildings: wet sprinkler+fire hydrant+alarm linkage, with the most stable cost-effectiveness.
气体灭火有个硬前提:防护区建议密闭,门窗缝隙做封堵,否则浓度达不到,等于白喷;有人常驻房间要带延时和声光报警,先疏散再释放。
There is a hard premise for gas fire extinguishing: the protective area must be sealed, and the gaps between doors and windows must be sealed, otherwise the concentration cannot be reached, which is equivalent to white spraying; If someone is stationed in the room, they should have a delay and sound and light alarm, evacuate first and then release.
采购端别光看单价。气体瓶组、喷头、报警阀、比例混合装置,建议查3C和检测报告,防护区容积、灭火浓度、浸渍时间让厂家出计算书。大空间项目提前核射流半径和探测盲区,避免验收时补装。
Don't just look at the unit price on the purchasing end. The gas cylinder group, nozzle, alarm valve, and proportional mixing device must be checked for 3C and testing reports. The manufacturer must provide calculation sheets for the volume of the protective zone, fire extinguishing concentration, and immersion time. Advance nuclear jet radius and detection blind spots for large space projects to avoid installation during acceptance.
系统不是堆设备,是“火在哪着、烧什么、谁在场、怎么控损失”四件事算明白。
The system is not a pile of equipment, it is about understanding four things: where the fire is, what it is burning, who is present, and how to control losses.