电控消防水炮为电动有线和无线遥控两种直流驱动控制方式,实现操作人员能够在远距离直接控制消防炮射水角度,能很好的保护灭火人员的人身。下面川消小编来讲讲电控消防水炮安装运输不合格的后果吧。
The electric fire water monitor adopts two DC drive control methods: electric wired and wireless remote control, which enables operators to directly control the water injection angle of the fire monitor from a long distance, effectively protecting the personal safety of firefighters. Next, let's talk about the consequences of unqualified installation and transportation of electronic fire water monitors.
1、若不冲洗,则不仅会使电动阀关闭不严,还会使杂物堵塞水炮炮嘴,进而影响水炮射程和流量。
1. If not flushed, not only will the electric valve not be tightly closed, but it will also cause debris to block the nozzle of the water cannon, thereby affecting the range and flow rate of the water cannon.
2、若与其他系统共用一个泵房系统,则水炮管网压力达不到额定工作压力
2. If sharing a pump room system with other systems, the pressure of the water cannon pipeline network cannot reach the rated working pressure
3、若不装,则管道内有杂质会使电动阀关闭不严,进而出现长期漏滴水现象以及会堵住炮口。这会造成后期维护难度很大。
3. If not installed, impurities in the pipeline will cause the electric valve to close loosely, leading to long-term water leakage and blockage of the gun mouth. This will make maintenance difficult in the later stage.
4、若装反,则会造成电动阀开关相反,调试水炮时现场控制箱显示关阀,实际是开阀,造成误喷水。
4. If installed in the wrong direction, it will cause the electric valve to switch in the opposite direction. When debugging the water cannon, the on-site control box shows that the valve is closed, but in reality, it is open, causing incorrect water spraying.
5、若安装距离过近,电动阀转动时,挡板会被法兰卡住导致关闭不严、电动阀烧坏,以及射水流量不够
5. If the installation distance is too close, the baffle will be stuck by the flange when the electric valve rotates, resulting in loose closure, burnt electric valve, and insufficient water injection flow rate
川消
6、若太高,则不方便现场施工和日后检修维护。
6. If it is too high, it will be inconvenient for on-site construction and future maintenance.
7、20-80L/S为DN100;100-120L/S为DN150;150-200L/S为DN200;其他流量请联系厂家,若小于该标准,则不符合消防验收标准。
7. 20-80L/S is DN100; 100-120L/S is DN150; 150-200L/S is DN200; For other flow rates, please contact the manufacturer. If it is less than this standard, it does not meet the fire acceptance standards.
8、20-80L/S为DN100;100-120L/S为DN150;150-200L/S为DN200;其他流量请联系厂家会造成水炮转动或喷水颤动避免造成法兰之间漏水,损坏水炮电子元件
8. 20-80L/S is DN100; 100-120L/S is DN150; 150-200L/S is DN200; For other flow rates, please contact the manufacturer to avoid water leakage between flanges and damage to the electronic components of the water cannon, which may cause rotation or water jet vibration
9、水炮控制箱控制系统为电路板时,须在安装水炮控制箱前将地址码设定好,拨码方式:1号炮拨1,2号炮拨2,3号炮拨1、2,4号炮拨3,以此类推,控制箱拨码为二进制。否则将会影响后期水炮调试增加不必要的麻烦。
9. When the control system of the water cannon control box is a circuit board, the address code must be set before installing the water cannon control box. The dialing method is: 1 for gun 1, 2 for gun 2, 1, 2 for gun 3, 3 for gun 4, and so on. The dialing code of the control box is binary. Otherwise, it will affect the later water cannon debugging and increase unnecessary trouble.
10、水炮控制箱控制系统为继电器时,则无需编码。会影响水炮的正常旋转
10. When the control system of the water cannon control box is a relay, there is no need for coding. It will affect the normal rotation of the water cannon
11、若距吊顶太近,则炮嘴仰起喷水会打到顶棚上。
11. If it is too close to the suspended ceiling, the nozzle will lift up and spray water onto the ceiling.
12、若不是,则容易造成通讯故障(RS485故障);视频模糊。
12. If not, it is easy to cause communication failure (RS485 failure); Video blurring.
电控消防水炮安装运输不合格的后果相关内容就讲解到这里了,您对此有怎样的疑惑或者需求可以随时来我们网站http://www.cx-fire.com进行咨询了解!