Fire hydrants can be seen everywhere in residential areas, parks, and roads. Their function is to eliminate the fire source, reduce the ignition point and isolate combustion-supporting materials. Fire hydrants are divided into indoor fire hydrants and outdoor fire hydrants, which are one of the indispensable fire fighting equipment to protect fire safety. What are the requirements of the installation specifications for outdoor fire hydrants? Let's have a look with Sichuan Xiaobian.
1.基本的要求就是室外消防栓应该安装在明显的位置,并且还要出水方便,这样急救灭火的时候才不会耽误时间。在气候温暖的地面安装地上式消防栓,在气候寒冷地面安装地下式消防栓,地下式消防栓还需要在地面设置安装固定的标志。
1. The basic requirement is that the outdoor fire hydrant should be installed in an obvious position, and it should be convenient to get out of the water, so that the time will not be delayed in the emergency fire fighting. The aboveground fire hydrant shall be installed on the ground with warm climate, and the underground fire hydrant shall be installed on the ground with cold climate. The underground fire hydrant shall also be installed with fixed signs on the ground.
2.居住区或市政府的室外消防栓应该沿着道路安装,当道路超过60m时,应该要在道路两旁设置,并且要靠近十字路口。室外消火栓的设置间隔不应该大于120m,距离道路边缘不能超过2m,距离建筑外墙不能小于5m,如果是高层建筑,距离外墙不能大于40m,距离一般建筑外墙不能大于150m。
2. Outdoor fire hydrants in residential areas or municipal governments should be installed along the road. When the road is more than 60m, they should be installed on both sides of the road and close to the intersection. The setting interval of outdoor fire hydrant shall not be more than 120m, the distance from the road edge shall not be more than 2m, and the distance from the external wall of the building shall not be less than 5m. For high-rise buildings, the distance from the external wall shall not be more than 40m, and the distance from the external wall of general buildings shall not be more than 150m.
川消
3.工业企业单位的室外消防栓应该在工艺装置区、储罐区这些装置的周围安装设置,间距不应该大于60m,如工艺装置区,如果装置的宽度大于120m,应该在装置的周围适当增加消防栓,对于储罐区,消防栓应设置在防火堤外,且储罐区消防栓的可使用范围应大于15m,否则不算入可使用的范围之内。消防栓的栓口直径规范大小为150m。
3. The outdoor fire hydrants of industrial enterprises should be installed around the process unit area and storage tank area, and the spacing should not be greater than 60m. For example, in the process unit area, if the width of the device is greater than 120m, the fire hydrants should be appropriately added around the device. For the storage tank area, the fire hydrants should be set outside the fire dike, and the usable range of the fire hydrants in the storage tank area should be greater than 15m, otherwise they should not be included in the usable range. The diameter of fire hydrant mouth is 150 m.
4.室外消防栓的数量应根据它保护的范围、流量和用量进行综合计算,每一只消防栓的流量是10~15L/S。对于高层建筑,室外消防栓的保护大范围是40m,对于多层建筑,室外消防栓的保护范围在150m之内,如果所需要的消防栓流量不大于15L/S时,还可以不用设置室外消防栓,仅用室内消防栓就可以了。
4. The number of outdoor fire hydrants shall be comprehensively calculated according to its protection scope, flow and consumption. The flow of each fire hydrant is 10-15L/S. For high-rise buildings, the protection range of outdoor fire hydrants is 40m, and for multi-storey buildings, the protection range of outdoor fire hydrants is within 150m. If the required flow of fire hydrants is not more than 15L/S, outdoor fire hydrants can not be set, only indoor fire hydrants can be used.
在发生火灾的时候,它可以急救灭火,拯救生命。按规定室外消防栓的水不得擅用,每年少检查一次。曾大家可以对照以上室外消防栓安装规范详细说明,看看自己身边的室外消防栓安装是否规范。更多相关内容就来我们网站http://www.cx-fire.com咨询吧!
In case of fire, it can give first aid to extinguish the fire and save lives. According to the regulations, the water of outdoor fire hydrants shall not be used without authorization, and shall be inspected at least once a year. You can refer to the above specifications for the installation of outdoor fire hydrants to see if the installation of outdoor fire hydrants around you is standard. Come to our website for more relevant content http://www.cx-fire.com Ask!