川消消防软管卷盘的概述以及功能

来源:http://www.cx-fire.com/ 日期:2023-02-14

川消消防软管卷盘是一种灭火装置,由阀门、输入管、软管、喷枪等组成。并能在迅速展开软管的过程中喷洒灭火剂。发生火灾时,消防人员用它来连接水管灭火。打开柜子,松开消防卷盘,接上水管,打开水阀,灭火。
Chuanxiao fire hose reel is a fire extinguishing device, which is composed of valve, input pipe, hose, spray gun, etc. The fire extinguishing agent can be sprayed during the rapid expansion of the hose. In case of fire, firefighters use it to connect the water pipe to extinguish the fire. Open the cabinet, loosen the fire reel, connect the water pipe, open the water valve, and put out the fire.
消防水带卷盘又称消防水带卷盘,由线圈、软管和铜矛头组成。使用时可直接从线圈中抽出,方便易操作,主要用于扑灭初期火灾。消防软管由软管、软管接头和水枪组成。需要两个人来操作。把软管放在一边,一端接在消防栓的闸阀上,另一端接在水枪上,操作起来比较复杂,对灭火有重要作用。
Fire hose reel, also known as fire hose reel, is composed of coil, hose and copper spearhead. When in use, it can be directly pulled out of the coil, which is convenient and easy to operate, and is mainly used to put out the initial fire. The fire hose is composed of hose, hose connector and water gun. Two people are required to operate. Put the hose on one side, connect one end to the gate valve of the fire hydrant, and connect the other end to the water gun. The operation is complex and plays an important role in fire fighting.
消防软管卷盘:酒店、重要写字楼、一级商业建筑、会展建筑、综合建筑等。其他建筑高度超过100米的高层建筑应设置消防卷盘,其用水量可不计入消防总用水量。消防卷盘之间的距离应保证水流能到达室内地面的任何部位,消防卷盘的安装高度应便于接近、灵活、不卡死。火轮的插头直径应为25毫米;配备直径不小于19mm的胶带;卷盘消防喷嘴的直径不小于6.00毫米。
Fire hose reels: hotels, important office buildings, first-class commercial buildings, exhibition buildings, comprehensive buildings, etc. Other high-rise buildings with a height of more than 100 meters shall be equipped with fire reels, and their water consumption may not be included in the total fire water consumption. The distance between fire reels shall ensure that the water can reach any part of the indoor ground. The installation height of fire reels shall be easy to access, flexible and not stuck. The plug diameter of the fire wheel shall be 25 mm; Provide adhesive tape with a diameter of not less than 19mm; The diameter of the reel fire nozzle shall not be less than 6.00 mm.
川消
功能如下:
The functions are as follows:
消防卷盘直径DN25.主要用于初期灭火。消防水带直径DN65.需要两个人操作,主要用于中期火灾。消防软管卷盘:打开消防栓箱的门,然后将消防自救托盘对准右侧,然后解锁,调整角度。
The diameter of fire reel is DN25. It is mainly used for initial fire extinguishing. The diameter of fire hose is DN65. It needs two people to operate, and is mainly used for medium term fire. Fire hose reel: first open the door of the fire hydrant box, then align the fire self-rescue tray to the right, then unlock and adjust the angle.
左手握住卷盘的水枪头,右手握住消火栓箱的门,轻轻拉出水龙带,然后将水枪头拉到着火点附近,再用一只手握住水枪头。另一只手打开球阀喷水,均匀喷洒灭火水覆盖着火点。确认火源已完全熄灭后,关闭水枪闸阀,返回消火栓箱,轻轻转动水龙带卷盘,将消防自救卷盘完全收回消火栓箱内,放置并关闭消火栓箱门,使用完毕。
Hold the water gun head of the reel with your left hand, hold the door of the fire hydrant box with your right hand, gently pull out the hose, then pull the water gun head to the vicinity of the ignition point, and then hold the water gun head with one hand. Open the ball valve with the other hand to spray water, and evenly spray the fire extinguishing water to cover the ignition point. After confirming that the fire source has been completely extinguished, close the water gun gate valve, return to the fire hydrant box, gently turn the hose reel, fully retract the fire self-rescue reel into the fire hydrant box, place and close the fire hydrant box door, and use it.
以上就是消防软管卷盘的相关内容介绍了,您对此有怎样的疑惑或者需求就来我们网站http://www.cx-fire.com咨询了解吧!
The above is the introduction of the fire hose reel. If you have any doubts or needs, please come to our website http://www.cx-fire.com Ask about it!
上一篇:七氟丙烷气体灭火系统的报警系统设计要求
下一篇:细水雾喷头该如何选择及布置?