大空间场所适合安装消防水炮灭火系统,这已经在众多项目工程中得以证明,那么在选型及安装方面,一直都是大家所关注的几个点,比如说哪类场所要用多大流量的水炮,哪类场所需要用防爆消防炮等等,具体这些在规范中有无说明呢?今天川消小编就来为您讲解一番。
Large space places are suitable for installing fire water monitor fire extinguishing system, which has been proved in many project projects. In terms of model selection and installation, we have always been concerned about several points, for example, which kind of places need to use water monitor with large flow, which kind of places need to use explosion-proof fire monitor, and so on. Are these specified in the specification? Today, Sichuan Xiaobian will explain it to you.
在新规范中,将固定消防炮和自动跟踪定位射流灭火系统的内容统一规整在了一起,这样对于灭火系统的设计有了更为清晰条例的汇总,其中关于大空间场所选择消防水炮灭火系统的规定,主要有以下几个方面。
In the new specification, the contents of the fixed fire monitor and the automatic tracking and positioning jet fire extinguishing system are unified and regulated together, so that the design of the fire extinguishing system has a clearer summary of regulations. Among them, the provisions on the selection of fire water monitor fire extinguishing system in large space mainly include the following aspects.
1、自动消防炮灭火系统中单台炮的流量,对于民用建筑,不应小于20L/s;对于工业建筑,不应小于30L/s。
1. The flow of a single monitor in the automatic fire monitor extinguishing system shall not be less than 20L/s for civil buildings; For industrial buildings, it shall not be less than 30L/s.
川消
2、持续喷水时间不应小于1.0h。
2. The continuous water spraying time shall not be less than 1.0h.
3、系统应具有自动控制、消防控制室手动控制和现场手动控制的启动方式。消防控制室手动控制和现场手动控制相对于自动控制应具有优先权。
3. The system shall have automatic control, manual control in fire control room and on-site manual control. Manual control in fire control room and on-site manual control shall have priority over automatic control.
4、自动消防炮灭火系统和喷射型自动射流灭火系统在自动控制状态下,当探测到火源后,应少有2台灭火装置对火源扫描定位和少1台且多2台灭火装置自动开启射流,且射流应能到达火源。
4. The automatic fire monitor fire extinguishing system and the automatic jet fire extinguishing system are under automatic control. When the fire source is detected, at least two fire extinguishing devices should scan and locate the fire source, and at least one and more fire extinguishing devices should automatically start the jet, and the jet should be able to reach the fire source.
5、喷洒型自动射流灭火系统在自动控制状态下,当探测到火源后,对应火源探测装置的灭火装置应自动开启射流,且其中应少有一组灭火装置的射流能到达火源。
5. When the fire source is detected, the fire extinguishing device corresponding to the fire source detection device shall automatically start the jet when the spray type automatic jet fire extinguishing system is under automatic control, and the jet of at least one group of fire extinguishing devices can reach the fire source.
规范前四条说的都是大家所熟知的消防水炮灭火系统,第五条则是对于大空间智能喷头的规定,如果有些场所受到高度或者内部结构的影响,不适宜选择消防水炮灭火系统的话,就可以考虑大空间智能喷头,这一点在很多的项目工程设计中就有体现。
The first four articles of the specification are all about the well-known fire water monitor fire extinguishing system, and the fifth article is about the provisions of the large-space intelligent sprinkler. If some places are affected by the height or internal structure and it is not suitable to choose the fire water monitor fire extinguishing system, the large-space intelligent sprinkler can be considered, which is reflected in many project engineering designs.
大空间场所选择消防水炮灭火系统的规定相关内容就讲解到这里了,您对此有怎样的疑惑或者需求,就来我们网站http://www.cx-fire.com咨询!