消防炮的结构有着底座、进水管、回转体、集水管和射流调节环、手把、锁紧机构等组成,这些是消防炮比较重要的组成部件,也是和消防炮的使用功能密切相关的。今天川消小编为大家介绍一下消防炮在日常生活中的功能和使用要求,希望对大家能有所帮助。
The structure of fire monitor is composed of base, water inlet pipe, swivel, water collecting pipe, jet regulating ring, handle, locking mechanism, etc. These are important components of fire monitor and are closely related to the use function of fire monitor. Today, the editor of Sichuan Xiaoxiao will introduce the functions and use requirements of fire monitor in daily life, hoping to help you.
1.远控消防炮应同时具有手动功能。
1. Remote control fire monitor shall have manual function at the same time.
2.消防炮应满足相应使用环境和介质的防腐蚀要求。
2. The fire monitor shall meet the corrosion protection requirements of the corresponding service environment and media.
3.安装在室外消防炮塔和设有护栏的平台上的消防炮的俯角均不宜大于50°,安装在多平台消防炮塔的低位消防炮的水平回转角不宜大于220°。
3. The depression angle of the fire monitor installed on the outdoor fire turret and the platform with guardrail should not be greater than 50 °, and the horizontal rotation angle of the low level fire monitor installed on the multi-platform fire turret should not be greater than 220 °.
4.室内配置的消防水炮的俯角和水平回转角应满足使用要求。
4. The depression angle and horizontal rotation angle of the indoor fire water monitor shall meet the use requirements.
5.室内配置的消防水炮宜具有直流—喷雾的无级转换功能。
5. The indoor fire water monitor should have the DC spray stepless conversion function.
川消
关于消防炮的使用要求
Requirements for use of fire monitor
一、室内消防炮的布置数量不应少于两门,其布置高度应保证消防炮的射流不受上部建筑构件的影响,并应能使两门水炮的水射流同时到达被保护区域的任一部位。室内系统应采用湿式给水系统,消防炮位处应设置消防水泵启动按钮。设置消防炮平台时,其结构强度应能满足消防炮喷射反力的要求,结构设计应能满足消防炮正常使用的要求。
1、 The number of indoor fire monitors shall not be less than two, and the arrangement height shall ensure that the jet of the fire monitor is not affected by the upper building components, and the water jet of the two water monitors can reach any part of the protected area at the same time. The indoor system shall adopt the wet water supply system, and the fire pump start button shall be set at the fire gun position. When the fire monitor platform is set, its structural strength shall meet the requirements of fire monitor ejection reaction, and its structural design shall meet the requirements of normal use of fire monitor.
二、室外消防炮的布置应能使消防炮的射流完全覆盖被保护场所及被保护物,且应满足灭火强度及冷却强度的要求。
2、 The outdoor fire monitor shall be arranged so that the jet of the fire monitor can completely cover the protected place and the protected object, and meet the requirements of fire extinguishing intensity and cooling intensity.
1、消防炮应设置在被保护场所常年主导风向的上风方向;
1. The fire monitor shall be set in the upwind direction of the perennial dominant wind direction of the protected place;
2、当灭火对象高度较高、面积较大时,或在消防炮的射流受到较高大障碍物的阻挡时,应设置消防炮塔。
2. When the fire extinguishing object is high in height and large in area, or when the jet of the fire monitor is blocked by a large obstacle, the fire turret shall be set.
三、消防炮宜布置在甲、乙、丙类液体储罐区防护堤外,当不能满足第2条的规定时,可布置在防护堤内,此时应对远控消防炮和消防炮塔采取有效的防爆和隔热保护措施。
3、 The fire monitor should be arranged outside the protective dike of Class A, B and C liquid storage tank area. If it cannot meet the requirements of Article 2, it can be arranged inside the protective dike. At this time, effective explosion-proof and thermal insulation protection measures should be taken for the remote control fire monitor and fire turret.
四、液化石油气、天然气装卸码头和甲、乙、丙类液体、油品装卸码头的消防炮的布置数量不应少于两门,泡沫炮的射程应满足覆盖设计船型的油气舱范围,水炮的射程应满足覆盖设计船型的全船范围。
4、 The number of fire monitors in the liquefied petroleum gas and natural gas loading and unloading wharves and Class A, B and C liquid and oil product loading and unloading wharves shall not be less than two. The range of foam monitors shall meet the range of oil and gas tanks covering the design ship type, and the range of water monitors shall meet the range of the whole ship covering the design ship type.
以上内容就是关于消防炮消防炮在日常生活中的功能和使用要求的全部介绍,希望对大家能有所帮助,后期有需要可以电话联系我们或者关注我们的网站http://www.cx-fire.com都可以,我们会定期更新内容,为消费者答疑解惑。
The above content is a complete introduction to the functions and use requirements of fire monitors in daily life. I hope it can help you. If you need later, you can call us or pay attention to our website http://www.cx-fire.com Yes, we will update the content regularly to answer questions for consumers.