联系我们
来源:http://www.cx-fire.com/ 日期:2026-01-16
室内消火栓是建筑内扑救初起火灾的消防设施,也是我们常见的消防设施之一。消火栓箱是放置消火栓及其附件的一个场所,其内一般放置如下的设施、设备及器材:
Indoor fire hydrants are fire-fighting facilities used to extinguish initial fires in buildings and are also one of the common fire-fighting facilities. A fire hydrant box is a place where fire hydrants and their accessories are placed, generally containing the following facilities, equipment, and devices:
1、消防给水管道及消火栓接口
1. Fire water supply pipeline and fire hydrant interface
室内消防给水管道铺设到消火栓箱内,并在消火栓箱内和消火栓接口进行连接,要求消火栓接口的中心距地1.1米,同时要求消火栓接口垂直墙面或与墙面平行栓口垂直向下,且栓口不得影响操作和消火栓箱的门关闭、栓口的直径应为65mm;
The indoor fire water supply pipeline is laid in the fire hydrant box and connected to the fire hydrant interface inside the fire hydrant box. The center of the fire hydrant interface is required to be 1.1 meters above the ground. At the same time, the fire hydrant interface is required to be perpendicular to the wall or parallel to the wall, and the hydrant interface should be vertically downward. The hydrant interface should not affect operation and the door of the fire hydrant box should be closed. The diameter of the hydrant interface should be 65mm;
2、消防水带及消防水枪
2. Fire hose and fire water gun
一般一个消火栓箱内配置消防水带一盘、消防水枪一支,要求水带的放置不得和箱底接触,以防水带吸收空气中的水分发生腐烂的情况,同时要求水带的长度不得大于25米;要求配置的水枪喷嘴口径不得小于19mm;
Generally, a fire hydrant box is equipped with one reel of fire hose and one fire water gun. It is required that the placement of the hose should not come into contact with the bottom of the box, so that the waterproof hose can absorb moisture from the air and prevent decay. At the same time, the length of the hose should not exceed 25 meters; The nozzle diameter of the water gun required to be configured shall not be less than 19mm;
3、消防软管卷盘
3. Fire hose reel
有的建筑由于规范要求必须设置消防软管卷盘,而消防软管卷盘一般都设置在消火栓箱内,消防软管卷盘设置时应满足软管长度不超过40米、软管胶带的内径不得小于19mm、栓口的直径为25mm、软管卷盘的喷嘴口径不得小于6mm;
Some buildings require the installation of fire hose reels due to regulatory requirements, and fire hose reels are generally installed inside the fire hydrant box. When installing fire hose reels, the length of the hose should not exceed 40 meters, the inner diameter of the hose tape should not be less than 19mm, the diameter of the hydrant mouth should be 25mm, and the nozzle diameter of the hose reel should not be less than 6mm;
4、灭火器
4. Fire extinguisher
有的消火栓箱分为上下两部分,上面放置消火栓及其附件,下面放置灭火器,一般建筑的火灾类型都是A类火灾、B类火灾或C类火灾,所以配置ABC干粉灭火器均适用,一个点配置的灭火器数量由计算确定,但一个配置点配置的灭火器不得少于2具且不得多于5具。
Some fire hydrant cabinets are divided into upper and lower parts, with fire hydrants and their accessories placed on the top and fire extinguishers placed on the bottom. Generally, the fire types in buildings are Class A, Class B, or Class C fires, so ABC dry powder fire extinguishers are applicable. The number of fire extinguishers configured at one point is determined by calculation, but the number of fire extinguishers configured at one configuration point shall not be less than 2 and not more than 5.
本文由 消火栓箱 友情奉献.更多有关的知识请点击 http://www.cx-fire.com/ 真诚的态度.为您提供为全面的服务.更多有关的知识我们将会陆续向大家奉献.敬请期待.