川消气体灭火系统主要用在不适于设置水灭火系统等其他灭火系统的环境中,比如计算机机房、重要的图书馆档案馆、移动通信基站(房)、UPS室、电池室、一般的柴油发电机房等。那么气体灭火系统问题怎么处理?与小编一起来看看吧。
Chuanxiao gas fire extinguishing system is mainly used in the environment where water fire extinguishing system and other fire extinguishing systems are not suitable, such as computer room, important library and archives, mobile communication base station (room), UPS room, battery room, general diesel generator room, etc. How to deal with the problem of gas fire extinguishing system? Let's have a look with Xiaobian.
1、施工队不能提供气体输送管的试压数据,只是口头上告知试过压了,具体是何时试压?试压人员是谁?都无法提供。所以是否试过压只能是个问号。
1. The construction team can't provide the pressure test data of the gas transmission pipe, but only tells verbally that the pressure test is excessive. When is the pressure test? Who is the pressure tester? Could not provide. Therefore, whether to test overvoltage can only be a question mark.
2、申请调试前施工操作人员对产品不作细致的了解。结果调试时出现声光报警不动作,报警点无法打印。要其整改时反而提出用备用电池时是不能打印的论点。咨询了生产厂家后才得到无其之说的结论。
2. Before applying for commissioning, the construction operators do not have a detailed understanding of the product. Results the audible and visual alarm did not act during debugging, and the alarm point could not be printed. When they were asked to rectify, they argued that they could not print when using backup batteries. After consulting the manufacturer, we came to a conclusion without explanation.
3、对气体灭火的性质了解不到位。防护区的门窗只是用一般性的材料和玻璃。在施工中不能提出异议,到调试验收中才发现该问题为时已晚,特别是防护区的门应是能自动关闭的也不清楚,也就太不应该了。
3. The nature of gas fire extinguishing is not well understood. Doors and windows in the protection area are only made of general materials and glass. We can't raise any objection during construction. It's too late to find out the problem until commissioning and acceptance. In particular, it's not clear whether the door of the protection area can be closed automatically, which is too inappropriate.
川消
4、气体储存室与配电间合用,这是不许可的。储存室的通道、应急照明、门、窗的防火等级、开启方向和储存室的排风装置关系到人身应予重视。
4. It is not allowed to share the gas storage room with the power distribution room. The passageway, emergency lighting, fire rating and opening direction of doors and windows of the storage room and the exhaust device of the storage room are related to personal safety and should be paid attention to.
气体灭火系统一般由瓶组、选择阀、喷头、单向阀、集流管、连接管、泄放装置、驱动装置、检漏装置、信号反馈装置、低泄高封阀、管路管件等部件构成,在使用中免不了会有问题存在,您要提前了解好避免掉。更多事项就来我们网站http://www.cx-fire.com一起了解吧!
The gas fire extinguishing system is generally composed of cylinder group, selector valve, spray nozzle, one-way valve, manifold, connecting pipe, safety relief device, drive device, leakage detection device, signal feedback device, low discharge and high seal valve, pipeline fittings and other components. Problems are inevitable in use. You should know in advance to avoid them. Come to our website for more information http://www.cx-fire.com Let's get to know each other!