按动作方式归类为开启式细水雾喷头、闭式细水雾喷头、切分喷嘴、又高又大室内空间专用型喷嘴、超细水雾喷头等100各种不同场所运用的髙压细水雾喷头。
According to the action mode, it can be classified into 100 high-pressure water mist nozzles used in different places, such as open water mist nozzles, closed water mist nozzles, split nozzles, high and large indoor space dedicated nozzles, and ultra-fine water mist nozzles.
髙压细水雾喷头分成分离式喷嘴、闭式喷嘴、隔开喷嘴、又高又大室内空间专用型喷嘴、超细水雾喷头等。每一个喷嘴包括1个或是好几个喷头,由喷嘴本身、喷头座、喷嘴、引流设备和过滤网构成,在髙压的作用下,运用离心式、碰撞或水射流等机械设备方法将雾水化作μm等级的雾水。
High pressure water mist nozzles are divided into separate nozzles, closed nozzles, separated nozzles, special nozzles for high and large indoor spaces, ultra-fine water mist nozzles, etc. Each nozzle includes one or several nozzles, which are composed of the nozzle itself, nozzle seat, nozzle, drainage equipment and filter screen. Under the action of high pressure, centrifugal, collision, water jet and other mechanical equipment methods are used to turn the mist into water μ M level fog water.
根据保护对象的火灾危险性及空间尺寸选用高压细水雾喷头:
High pressure water mist nozzle shall be selected according to the fire hazard and space size of the protected object:
公共区吊顶采用闭式K=1.25喷头,喷头的安装间距不大于3m,不小于2m,距墙不大于1.5m。
The closed k = 1.25 sprinkler is used for the ceiling in the public area. The installation spacing of the sprinkler is not more than 3m, not less than 2m, and not more than 1.5m from the wall.
川消
有地板层的机房工作层采用开式K=0.45喷头,喷头的安装间距不大于3m,不小于1.5m,距墙不大于1.5m。
The working floor of the machine room with the floor adopts the open type K = 0.45 nozzle. The installation spacing of the nozzle is not more than 3m, not less than 1.5m, and not more than 1.5m from the wall.
地板层采用开式K=0.17喷头,喷头的安装间距不大于3m,不小于1.5m,距墙不大于1.5m。
Open type K = 0.17 nozzles shall be used for the floor. The installation spacing of nozzles shall be no more than 3m, no less than 1.5m and no more than 1.5m from the wall.
其余保护区均采用开式K=0.95喷头,喷头的安装间距不大于3,不小于1.5m,距墙不大于1.5m。
Other protection areas adopt open type K = 0.95 nozzles. The installation spacing of nozzles is not more than 3, not less than 1.5m, and not more than 1.5m from the wall.