川消_萃联
气体灭火系统
自动喷水灭火系统
当前位置:首页 > 新闻中心自动消防水炮的特点以及安装步骤

自动消防水炮的特点以及安装步骤

来源:http://www.cx-fire.com/ 日期:2022-10-06

自动消防水炮(亦称智能消防水炮、大空间自动消防炮、自动扫描水炮)是集报警、灭火于一体的高科技消防产品,那么自动消防水炮的特点以及安装步骤是怎样的呢?下面川消小编为您讲解!
Automatic fire monitor (also known as intelligent fire monitor, large space automatic fire monitor, automatic scanning water monitor) is a high-tech fire protection product integrating alarm and fire fighting. What are the characteristics and installation steps of automatic fire monitor? Now let's talk about it!
自动消防水炮的特点
Features of automatic fire water monitor
自动消防水炮装置具有主动探测火源、自动定位、自动对准着火点喷射水流进行灭火、灭火后复检,确认火情灭失后自动恢复初始状态的特点。
The automatic fire monitor device has the characteristics of actively detecting the fire source, automatically positioning, automatically aiming at the ignition point to spray water for fire extinguishing, rechecking after fire extinguishing, and automatically restoring the initial state after confirming the fire loss.
产品安装方便,操作简单,维护费用低维护简单,灭火效率高,大程度地使火势在起始阶段就扑灭火灾,具有很高的灭火效率。
The product is easy to install, simple to operate, low in maintenance cost, simple in maintenance, and high in fire extinguishing efficiency, which makes the fire extinguish at the initial stage to a large extent, and has high fire extinguishing efficiency.
本产品广泛应用于、车站、机场、仓库、厂房、体育馆、礼堂、会展中心、宾馆、停车场等室内大空间开阔或人流密集场所,可以及时时间控制火势,防止火灾蔓延。
This product is widely used in shopping malls, stations, airports, warehouses, factories, stadiums, auditoriums, exhibition centers, hotels, parking lots and other large indoor open spaces or crowded places, which can control the fire in time to prevent the spread of fire.
川消
自动消防水炮安装步骤
Installation steps of automatic fire water monitor
1.将自动灭火部件(自动消防水炮)的法兰与系统管网上的法兰对接,法兰端面用水平尺调成水平;并通过4个螺栓固定;
1. Connect the flange of the automatic fire extinguishing component (automatic fire monitor) with the flange on the system pipe network, and adjust the flange end face to be horizontal with a level ruler; And fixed by 4 bolts;
2.调整引线长度,保证灭火装置在转动的范围内无阻挡且不受引线长度限制;
2. Adjust the lead length to ensure that the fire extinguishing device is unobstructed within the rotation range and is not limited by the lead length;
3.连接电磁阀电源线;连接电源线,连接通信线,连接视频线(如需)。
3. Connect the solenoid valve power line; Connect the power cable, communication cable and video cable (if necessary).
4.连接现场控制箱电源输入,电源输出,终端通信线,控制台通信线(如有);
4. Connect the power input, power output, terminal communication line and console communication line of the field control box (if any);
5.安装初步完成。检查接线正确无误,即可通过现场手动控制箱进行加电测试;
5. Installation is preliminarily completed. Check that the wiring is correct, and then conduct the power on test through the on-site manual control box;
6.加电后,现场控制箱手动指示灯点亮,通讯指示灯闪动,即表明和灭火部件接线正常;
6. After power on, the manual indicator of the field control box lights up and the communication indicator flashes, indicating that the connection with the fire extinguishing parts is normal;
7.控制电磁阀开启闭合,如果电磁阀开启闭合正常,表面电磁阀接线正常。
7. The control solenoid valve is opened and closed. If the solenoid valve is opened and closed normally, the surface solenoid valve wiring is normal.
8.自动消防水炮初步安装完成。
8. The preliminary installation of automatic fire monitor has been completed.
自动消防水炮的特点以及安装步骤就讲解到这里了,您对此有什么想法可以随时来我们网站http://www.cx-fire.com进行分享交流!
The features and installation steps of the automatic fire water monitor are explained here. If you have any ideas about this, please come to our website at any time http://www.cx-fire.com Share and communicate!
上一篇:消火栓的使用方法步骤与使用注意事项
下一篇:预作用报警阀安装什么样的喷淋头