川消_萃联
气体灭火系统
自动喷水灭火系统

联系我们

  • 萃联(山东)消防设备有限责任公司
  • 电话:15508683119
  • 地址:山东省济南市历城区祝舜路44号
当前位置:首页 > 新闻中心消防泵故障的3大问题了解处理

消防泵故障的3大问题了解处理

来源:http://www.cx-fire.com/ 日期:2022-12-28

消防泵顾名思义,消防上用的泵,广泛应用于、水处理、消防等部门,是用来抽送各类液体,是创建无泄漏、无污染文明车间、文明工厂的理想用泵与消防系统的。下面川消小编来讲讲消防泵故障的3大问题了解处理。
As the name implies, fire pumps are widely used in environmental protection, water treatment, fire protection and other departments. They are used to pump all kinds of liquids. They are ideal pumps and fire protection systems for creating leak free, pollution-free and civilized workshops and factories. Now let's talk about the three major problems of fire pump failure.
问题一:消防泵震动严重
Problem 1: The fire pump vibrates severely
1.消防泵与电机轴不同心?
1. The fire pump is not concentric with the motor shaft?
调正,对准消防泵与电机轴心。
Align the fire pump and motor shafts.
2.消防泵轴弯曲?
2. The fire pump shaft is bent?
拆下校直或换新的。
Remove the straightening or replace it with a new one.
3.叶轮不平衡?
3. Impeller is unbalanced?
拆下找平衡。
Remove for balancing.
问题二:消防泵抽不出液体
Problem 2: The fire pump cannot pump out liquid
1.压出管路太细,管路损失太大?
1. The pressed out pipeline is too thin, and the pipeline loss is too large?
换适合的压出管路。
Replace with a suitable press out pipe.
2.使用扬程超过了设计扬程?
2. Does the operating lift exceed the design lift?
重新选消防泵。
Reselect the fire pump.
川消
3.吸入管或消防泵内没有排净气体?
3. Is there no gas discharged from the suction pipe or fire pump?
检修吸入管路并排净气体。
Maintain the suction pipe and discharge the gas.
4.吸上高度超过允许范围?
4. Does the suction height exceed the allowable range?
按允许吸上高度重新安装消防泵。
Reinstall the fire pump according to the allowable suction height.
5.输送热的、挥发性的介质?
5. Conveying hot and volatile media?
降低吸程或采用倒灌按装。
Reduce the suction head or use reverse filling.
6.转向反了?
6. The steering is reversed?
纠正转向。
Correct the steering.
7.没有灌注液体?
7. No liquid filled?
重新灌消防泵。
Recharge the fire pump.
8.吸入管、出水管或消防泵的流道堵塞?
8. Is the flow passage of suction pipe, outlet pipe or fire pump blocked?
杂物。
Eliminate sundries.
问题三:机械密封泄漏严重
Problem 3: Serious mechanical seal leakage
1.固定螺钉松动,使弹簧失去作用?
1. The fixing screw is loose, causing the spring to lose its function?
紧固螺钉或重新调整弹簧。
Tighten the screws or readjust the springs.
2.弹簧压力不足?
2. Insufficient spring pressure?
重新调整弹簧压缩量或换弹簧。
Readjust the spring compression or replace the spring.
3.静环装配歪斜?
3. Static ring assembly is skewed?
重装消防泵用静环。
Refit the static ring for the fire pump.
4.动换或静环端面腐蚀、磨损或刮伤?
4. Is the end face of the moving or stationary ring corroded, worn or scratched?
修复或更换坏的动环静环。
Repair or replace the damaged dynamic and static rings.
5.轴套加工精度和光洁度不够,影响了动环的轴向移动?
5. The machining accuracy and finish of the shaft sleeve are not enough, which affects the axial movement of the moving ring?
换加工精度合格的轴套。
Replace the shaft sleeve with qualified machining accuracy.
6.杂质、异物或介质结晶影响了动环的轴向移动或支撑在动、静环的端面之间?
6. Do impurities, foreign matters or medium crystals affect the axial movement of the moving ring or support between the end faces of the moving and stationary rings?
杂质、异物和结晶,清洗密封元件。
Eliminate impurities, foreign matters and crystals, and clean the sealing elements.
7.动环密封圈装配斜卷或腐蚀变形?
7. Rotating ring seal ring assembly is inclined or corroded and deformed?
重装或更换消防泵用动环密封圈。
Reassemble or replace the movable ring seal ring for the fire pump.
此外消防泵的选型应根据消防泵应用工程的工艺流程,给排水要求,从液体输送量、装置扬程、液体性质、管路布置以及操作运转条件等方面加以考虑。更多相关内容就来我们网站http://www.cx-fire.com进行咨询吧!
上一篇:每季度应对川消气体灭火系统进行1次综合检查
下一篇:维修人员检查拆卸压力式比例混合装置事项

相关产品 / Related products