The suspended superfine dry powder fire extinguishing device is easy to install and maintain, and is welcomed by the industry. Now, Sichuan Xiaobian will briefly introduce what should be paid attention to in the installation and later maintenance of the lower suspended superfine dry powder fire extinguishing device.
一、悬挂式超细干粉灭火装置的安装方法
1、 Installation method of suspended superfine dry powder fire extinguishing device
1)用2个膨胀螺钉(M10)将固定支架固定在保护区上方的混凝预制板上,将灭火装置上部吊环座旋入固定板下方的螺杆(M12),深度不小于15mm,装置安装应牢固,不得松动。启动模块可以安装在固定支架上。如图4所示。
1) Use two expansion screws (M10) to fix the fixed support on the concrete precast slab above the protection area, screw the upper ring seat of the fire extinguishing device into the screw (M12) below the fixed plate, and the depth shall not be less than 15mm. The device shall be firmly installed without loosening. The starting module can be installed on the fixed bracket. As shown in Figure 4.
2)将1个带钩的膨胀螺钉(M12)固定在保护区上方的混凝预制板上,再将装箱中吊环拧紧在灭火装置上部,吊环钩在膨胀螺钉弯钩处,插上定位销。启动模块可以挂在就近的墙壁或天花板上。如图5所示。
2) Fix one expansion screw (M12) with hook on the concrete precast slab above the protection area, tighten the lifting ring in the box on the upper part of the fire extinguishing device, hook the lifting ring on the hook of the expansion screw, and insert the positioning pin. The startup module can be hung on the nearby wall or ceiling. As shown in Figure 5.

需要注意的是,订货时应注明吊装方式,无特别说明时默认是吊环安装。
It should be noted that the lifting method should be indicated when ordering, and the lifting ring installation is defaulted when there is no special instructions.
二、悬挂式超细干粉灭火装置的维护
2、 Maintenance of suspended superfine dry powder fire extinguishing device
使用单位应建立维护管理制度,由专人负责定期检查。建议每6个月少对灭火装置进行一次检查。灭火装置一经开启或发现压力指示器指针指向红色区域时,必须重新再充装。
The user unit shall establish a maintenance management system, and special personnel shall be responsible for regular inspection. It is recommended to inspect the fire extinguishing device at least once every 6 months. Once the fire extinguishing device is opened or the pointer of the pressure indicator points to the red area, it must be refilled.
每12个月应进行一次综合检查,包括相关联动系统。必要时,取下灭火装置,检查灭火剂是否有结块现象,如果有,应该重新充装。
A comprehensive inspection shall be conducted every 12 months, including relevant linkage systems. If necessary, remove the fire extinguishing device, check whether the extinguishing agent is caked, and if so, refill it.
In addition, the superfine dry powder fire extinguishing device shall be suspended, and the water pressure test shall be carried out for the fire extinguishing agent powder tank every time it is recharged or every 5 years. It is not allowed to use again if the hydraulic test is unqualified. More relevant content will come to our website http://www.cx-fire.com Consult!