  如今很多企业单位都安装上了自动喷水灭火系统,防患于未然是必要的,那么安装完成后的验收工作是非常关键的,那么自动喷水灭火系统验收是什么?
  Now many enterprises are installed on the automatic sprinkler system, prevention is necessary, so the acceptance of the completion of the installation is very key, so what is the focus of the acceptance of the automatic sprinkler system?
  图纸、资料的审查
  初始设计图纸、施工图纸、设计变更及竣工图,喷头、水流指示器、报警阀组、消防水泵、消防水泵接合器及闸阀等主要设备的性能指标的资料和产品合格证书,隐蔽工程的施工验收记录、管道通水冲洗、打压试验记录、水泵等消防用电设备的试运转记录,工程质量事故的处理记录。
  Review of drawings and materials
  Initial design drawings, construction drawings, design changes and completion figure, nozzle, water flow indicator, alarm valve group, fire pump, fire pump adapter and gate valve performance of the main equipment of information and product certificate, take cover engineering construction acceptance records, pipeline water flushing, suppression test records, fire electrical equipment such as pump commissioning record, Handling record of engineering quality accident.
  系统安装情况的一般性检查
  检查消防水泵、水泵接合器、消防水池取水口、及闸阀等主要设备的安装与图纸是否相符,使用是否方便,有无正确的明显标志,有无外观损坏及明显缺陷。现场查看、测量喷头类型、布置间距、数量,管网的管材及管径、管网连接形式和质量、管道安装的位置及配水管设置的喷头数量,末端试水装置,管道减压措施,系统排水装置等。
  General check of system installation
  Check whether the installation of fire pump, water pump adapter, water inlet of fire pool, gate valve and other major equipment conform to the drawing, whether it is convenient to use, whether there is correct obvious mark, whether there is appearance damage and obvious defect. Check and measure the type, spacing and quantity of nozzles, pipe and pipe diameter of pipe network, connection form and quality of pipe network, installation position of pipe and number of nozzles set by water distribution pipe, end water testing device, pipe decompression measures, system drainage device, etc.
  系统综合性功能试验
  根据原设计的不同要求,对川消消防水泵分别进行自动、手动、远程和泵房内就地启动的试验;消防水泵组的主泵与副泵互为备用功能的相互切换试验;根据有关要求进行水压试验和气压试验;对报警控制装置功能进行检验;报警阀功能试验验;系统联动试验。
  System comprehensive function test
  According to the different requirements of the original design, the tests of automatic, manual, remote and local start-up of chuanxiao fire pump are carried out respectively. The switching test of main pump and auxiliary pump of fire pump group; To conduct hydrostatic and pneumatic tests according to relevant requirements; Check the function of alarm control device; Alarm valve function test; System linkage test.
  自动喷水灭火系统验收是什么?从三个方面开始验收,做好相关事项才能验收成功,细节方面的注意事项有很多,需要了解的话可以来网站www.cx-fire.com看看。
  What are the key points of automatic sprinkler system acceptance? Start from the three aspects of acceptance, do a good job of the relevant items to succeed in acceptance, there are many details of the matters needing attention, you can visit the website www.cx-fire.com.