川消消防泵使用之前需要进行调试工作
来源:http://www.cx-fire.com/ 日期:2022-05-06
几乎大部分的机械设备在使用之前都是需要进行调试的,只有这样才能知道该设备是不是能够进行下面的作业,消防泵也是如此,那么它的调试工作是怎样的呢?
Almost most of the mechanical equipment is needed to be debugged before use, only in this way can we know whether the equipment can carry out the following operations, fire pump is the same, so what is the debugging of it?
消防泵在运行前应注意调试,主要是使各方面的数值满足相关要求,并确保其能正常使用且无异常。调试过程中,有时会出现压力达不到规定要求的情况,所以此时需要考虑造成这种情况的原因很可能是电机逆转造成的,找到原因就要对症下药。
Fire pump should pay attention to debugging before operation, mainly to make all aspects of the value to meet the relevant requirements, and ensure that it can be used normally and no abnormality. In the process of debugging, sometimes the pressure can not meet the requirements of the situation, so at this time we need to consider the cause of this situation is likely to be caused by the reversal of the motor, to find the cause will be appropriate medicine.
电机逆转我们需要看到三相导线,交换它们的任意一个相序,就可以了。如果相序改变后仍有问题,那么消防泵的出口管道应做一些放空设施,当泵已经开始运行时,应调试出口阀,出口压力应达到一定值,这是正常的。如果达不到,就会影响消防泵的出路效应,或者导致水泵超压运行。
Motor reversal we need to see the three-phase wire, swap any of their phase sequence, can be solved. If there is still a problem after the phase sequence changes, then the outlet pipeline of the fire pump should do some venting facilities. When the pump has started to run, the outlet valve should be debutted, and the outlet pressure should reach a certain value, which is normal. If not, it will affect the fire pump outlet effect, or lead to pump overpressure operation.

下方泵也要定期进行检查和检查,以保持消防系统的电源和电路正常,电气设备正常。在检查的过程中消防泵的重量应该是均匀的并且没有异常的声音。那么,检查应该加油了。
The lower pump should also be checked and inspected regularly to keep the power supply and circuit of the fire protection system and the electrical equipment normal. The weight of the fire pump should be uniform and there should be no abnormal sound during the inspection. Well, the inspection should be refueled.
加油窗中点应作为标准,加油量应与中点线保持平衡。有时候不可能做到准确,所以稍微低于中点线就可以了。此外,检查抽水时间。这些数据需要记录下来。
The midpoint of refueling window should be taken as the standard, and the amount of refueling should be balanced with the midpoint line. Sometimes it's impossible to be accurate, so just a little below the midpoint line will do. Also, check the pumping time. This data needs to be recorded.
川消消防泵启动后,浮球应处于运行状态,排气管中不应有水。如果检查,恰好发现有水,需要应该更换垫圈,以确保密封体紧密,排气正常。检查定期,看看消防泵,各地的连接是否牢固,能否顺利运转。
After the fire pump is started, the floating ball should be in running state, and there should be no water in the exhaust pipe. If the inspection happens to find water, the gasket should be replaced to ensure that the sealing body is tight and the exhaust is normal. Check regularly to see whether the fire pump, the connection around the firm, can run smoothly.
川消消防泵使用之前需要进行调试工作相关内容便是以上这样了,如果您对该设备还有问题没有得到有效处理的话,可以来网站
www.cx-fire.com咨询我们!
Sichuan fire pump before the use of debugging work related content is the above, if you have a problem with the equipment has not been effectively dealt with, you can come to the website www.cx-fire.com consult us!