川消_萃联
气体灭火系统
自动喷水灭火系统
当前位置:首页 > 新闻中心讲解川消消防水炮的构造与功能

讲解川消消防水炮的构造与功能

来源:http://www.cx-fire.com/ 日期:2022-08-11

川消消防水炮的构造与功能是怎样的呢?实际上消防水炮由前段探测、火焰定位、信息处理、终端显示、记录报警、联动扑救等几部分组成。下面来详细讲讲。
What is the structure and function of Chuanxiao fire water monitor? In fact, the fire water monitor is composed of several parts, such as front detection, flame positioning, information processing, terminal display, recording alarm and linkage fire fighting. Let's talk about it in detail.
前段探测:它采用双波段感火焰探测技术,具有同时获取现场火灾信息和图像信息的功能。可根据火灾在燃烧过程中的光谱、色度、纹理、运动及频谱特性,通过控制中心对其传送来的信号进行职能化火灾判断,可以准确识别火灾并报警。
Front section detection: it adopts dual band flame detection technology, and has the function of acquiring on-site fire information and image information at the same time. According to the spectrum, chromaticity, texture, motion and spectrum characteristics of the fire in the combustion process, the control center can perform functional fire judgment on the signal transmitted from the fire, and can accurately identify the fire and give an alarm.
火焰定位:火焰探测器在巡检过程中一旦发现火情,立即发出报警信息,计算机在接受报警信号并经过系统确认后,由功率驱动模块控制消防水炮的水平电机和俯仰电机作旋转运动,消防水炮喷头带动火焰定位器进行水平方向和俯仰方向的火焰搜索。
Flame positioning: once a fire is found in the process of patrol inspection, the flame detector will immediately send out alarm information. After the computer receives the alarm signal and is confirmed by the system, the power drive module will control the horizontal motor and pitch motor of the fire water monitor to rotate. The fire water monitor nozzle will drive the flame locator to search for flames in the horizontal and pitch directions.
信息处理:信息处理主机是消防水炮系统的技术核心部分和集中控制部分,可对双波段摄像机采集的视频信号进行巡检,可控制数百路视频图像信号。主机利用火灾监控软件来处理火灾报警信号,进行再确认。并对经确认的火灾信号进行记录、显示及自动控制联动设备﹝警铃、水泵、录像机等﹞。系统报警响应时间一般不大于20秒。
Information processing: the information processing host is the technical core and centralized control part of the fire water monitor system. It can patrol the video signal collected by the dual band camera and control hundreds of video image signals. The host uses the fire safety monitoring software to process the fire alarm signal and reconfirm it. And record and display the confirmed fire signal and automatically control the linkage equipment (alarm bell, water pump, video recorder, etc.). The system alarm response time is generally no more than 20 seconds.
川消
终端显示:显示器设在消防控制中心,可以将整个建筑物分成多幅建筑平面图存放在主机的硬盘中,探测器也按实际位置标注在建筑平面图中。
Terminal display: the display is set in the fire control center, which can divide the whole building into several building plans and store them in the hard disk of the host. The detector is also marked in the building plan according to the actual position.
记录报警:由于消防水炮主机采用工业计算机,信息处理能力大幅度提高,可对各种数据进行的管理控制,包括系统运行记录。
Record and alarm: as the main machine of fire water monitor adopts industrial computer, the information processing capacity is greatly improved, and various data can be efficiently managed and controlled, including system operation records.
联动扑救:联动扑救是通过联动模块完成的,连动模块负责灭火设备与主机之间的协同工作,对主机的各种命令作出及时响应。
Linkage fire fighting: linkage fire fighting is completed through the linkage module, which is responsible for the cooperative work between the fire-fighting equipment and the host and makes timely response to various commands of the host.
要注意的是,在火灾扑救过程中,消防水炮系统的每一组成部分的工作是协调互动、相辅相成的。所以在平常中就要对其以及其部件好好维护保养,更多事项就来我们网站http://www.cx-fire.com咨询吧。
It should be noted that in the process of fire fighting, the work of each component of the fire water monitor system is coordinated, interactive and complementary. Therefore, it is necessary to properly maintain it and its parts in ordinary times. For more information, please visit our website http://www.cx-fire.com Consult.
上一篇:大空间智能型主动喷水灭火系统的调试过程
下一篇:川消湿式报警阀的日常维护注意事项

相关产品 / Related products